In this article I try to give you some pointers to make it easy to chose between the two popular content management systems. The basic difference between WordPress and Joomla is that Joomla is a portal- or community type site while WordPress is a blog. Both overlap each other in several areas and can be extended beyond their original purpose thanks to the use of plugins. You can find those plugins almost everywhere on the internet. Both have a large user base with a lively community where tips and tricks are shared. Both are free to use and many hosting providers have them as an option in their web tools section. Both have a large community of volunteer developers and commercial add-ons.

Aluminum Wiring Into a Service Panel

One breaker will go on to the barn about 75′ with wire. The other breaker the opposite direction with another wire about 65′ to an outdoor outlet for a heater this winter in the water trough. Considering you are installing what is likely 15A or 20A receptacles, you should be using 20A breakers. And then, due to the distance, your wire gauge is too small.

For a basic project in zip code with 1 sub-panel, the cost to Install an Electrical Sub-Panel starts at $1, – $1, per sub-panel. Actual costs will depend on job size, conditions, size options.

Modern inverters that convert DC battery power to AC power are able to supply many of the loads commonly found on boats and RV’s. These loads include microwaves, lighting, entertainment, and general-purpose outlets. Appropriate loads for an inverter are those that consume small or modest amounts of power and are run for an extended period of time, or large loads, like a microwave, which run for a short amount of time. Some loads are not appropriate for use with an inverter: Separating these two load groups is not difficult.

To accomplish this task, establish a separate load group sub panel in the distribution system. The one line diagram below Illustration 1 shows the concept.

How To Install A volt outlet or Dryer Outlet

Many of these involve car repair scams. Auto repair problems make up the largest group of consumer complaints. The National Highway Traffic Safety Administration estimates that consumers lose tens of billions of dollars each year due to faulty or unnecessary car repairs.

Sep 26,  · Is that an actual sub-panel or are ya re-using a main panel? I have a amp main panel in my garage with a 40Amp breaker in the main box. There is a screw that grounds the common and that has to be removed from the sub-panel if it was once a main. i was more concerned with how to actually tie in the wires to the box and hook up the.

I actually had no idea it was here. I’ve got a weird question that I think someone on here would know. I’m trying to get the correct wiring setup so when the inspector comes, he won’t fail my setup. I don’t expect he will check the generator cable, but I’d still like to ensure it’s setup correctly for my own safety. I have a Honda EU i generator which I’m going to use to connect to a generator panel and power a couple circuits in my house. The problem is that the panel in designed for v and has 2 hots, while the generator is only Obviously, I need to find a way to power both buses in the panel with v.

I know I cannot run any v loads, but that’s perfectly fine. I’m only running some lighting circuits and my fridge. I spoke briefly with an electrician and he said to jump the buses in the panel. Seemed logical and I was going to do that but then I thought about it a little more and realized how bad this could be.

I bought an L inlet box and L connector for my cable from the genny. That leaves a 30a plug on the exterior. If someone ever plugged in a 30a generator

Main Breaker Panel

Using quality lifting tools ensures not only the success of the job, but the safety of the workers in the jobsite as well. That’s why we at Advantage Rigging aim to provide only high quality lifting products to guarantee the safety of workers whether in construction, oil and gas extraction, or any industrial setting where heavy lifting and moving takes place. Having started as an on-site inspection and repair service for rigging hardware, we understand how important it is to have reliable lifting products in the field.

We’ve since branched out to provide quality lifting equipment including hooks and coupling links, nylon slings , poly chain slings , lifting slings , and more—all manufactured for long-term reliability and to ensure compliance with OSHA standards. Before making a purchase at our online store, be sure to be ready with the specifications you need.

In this video, This Old House host Kevin O’Connor explains how to install a stand-by generator. Steps: 1 Install electrical sub-panel with transfer switch beside the main electrical panel. 2 Redirect critical circuits from main panel to sub-panel.

Preparations In this case, the power was controlled by a amp breaker on the main breaker panel. I turned off the breaker. Then I removed the cover from the sub-panel that was getting a new circuit breaker. This situation is a little different from most houses. This house has a amp main breaker panel, which feeds 3 subsidiary breaker panels. This is a good technique for house wiring, although it does cost a little more. This method allowed me to shut off the power at the main panel, so the amp sub-panel had no live wires anywhere.

But there was still power to some parts of the house.

how to hook up a sub panel

I removed the metal cover and the home-made wiring shroud. The coiled-up large black cable red arrow is the sub-feed that supplies power to the new sub-panel. We left one large knock-out for the sub-feed cable. This cable needs to enter the main panel at arrow 1, so we had to re-route the cable behind all those other cables.

Jun 22,  · Due to baseboard electric heat provisions upstairs, and a number of other circuit needs, our main service box is a 40 circuit box, and immediately beside it, is a 24 circuit amp sub panel (has a amp circuit breaker located in the main amp panel to feed this amp sub panel).

Are you sure you want to delete this answer? Yes Sorry, something has gone wrong. Your wording is a little confusing, are you not sure how to connect in the main panel or the sub panel In your sub panel, you should NOT install a green bonding screw, and you should have a separate ground bar installed in the panel if you ordered a main lug only panel from Square D it should have come with the panel, otherwise you’ll need to buy a ground bar.

These are not electrically connected. The ground bar is screwed to the box and electrically connected to the box. The neutral is isolated from the box as long as the green screw is not installed. In the main panel, the grounds and neutral what you call common are connected together. This is the ONLY place they are ever connected together. The purpose of that connection is if a fault occurs, the current will go through the “ground” back to the source this has nothing to do with the earth.

If you connect neutral and ground anyplace else, you will get neutral current during normal operation on the ground wires. This is bad for two reasons:

Generac Power Systems

Email Shares 52 We get a lot of questions on our electric wiring articles from folks tackling electrical projects in their own home. One of the most common and intimidating parts of electrical work is dealing with the main breaker panel. This article provides an overview of a breaker panel. Some jurisdictions require you to be an electrician to perform any electrical work, even in your own home.

Aug 10,  · Electrical work is inherently dangerous and can be potentially deadly. Work only under the direct supervision of a licensed electrical contractor!

The two panels may be connected through the inverter in the battery back-up system. You will have an AC line coming from your main service panel which is connected to the “AC in” on the back-up system. The “AC out” is then sent to the sub-panel only, not back to the main panel. During a power outage, power will be supplied only to the backed up sub-panel, not to the main panel. This requires that you relocate specific circuits that you wish to have powered when the grid is down, to the new sub-panel.

This is best accomplished by a licensed electrician. The reason for wiring critical loads into a subpanel is twofold First, if you were to send the “AC out” from the back-up system to your main panel, you would be backfeeding a “down” grid. This is illegal and dangerous.

RV DC to AC Power Inverter

Do you need a sub-panel for your basement? Why, and how much will it cost? December 19, by Jason 6 Comments When you’re planning the wiring for you basement keep in mind that you may need to install a sub-panel. How much will it cost?

The sub panel can be located right beside / close by the main panel or in separate areas, if it is not for an accessory building or for use in a workshop then it will most likely be close to the main panel.

The detailed step-by-step instructions and pictures will simplify this more complex project. Figure 1 — Original Panel My customer had just purchased the house, and he needed to renovate his basement in order to accommodate his collection of reptiles, spiders, amphibians and other creatures. Figure 2 — Cuddly Snake! Figure 3 — Original Panel Cover Removed Planning The first step should always be planning, as a project such as this is fairly complex. Take the time to think through the necessary steps to complete the job, ensure that you have the appropriate tools and materials, and that all appropriate safety requirements are being followed.

Remember — Safety First! If you are at all unsure about tackling a project like this, leave it to a reputable electrical contractor. Good lighting is critical when working on this type of project, so I would recommend that you arrange for an external light source, such as a good battery operated light, or a portable generator outside. Run in an extension cord to a portable work light, or a trouble light. This will allow you to work in the original panel to make the required changes with the main breaker off, which will de-energize the bus bars in the panel.

Look at the area you have to work with and decide where you are going to mount the subpanel.